Cooling tower fill

750mm 950mm Cellular Cooling Tower Fill for Custom Packing Assemblies

WhatsApp QR Code WhatsApp QR
WeChat QR Code WeChat QR
Product Description

750mm & 950mm Cellular Cooling Tower Fill for Custom Packing Assemblies

This cellular cooling tower fill is available in two standard widths, 750mm and 950mm, with a 20mm corrugation pitch and a 90° channel arrangement. It can be manufactured in different lengths and sheet thicknesses to meet the packing dimensions required by individual cooling tower projects.

For this type of fill, we pay particular attention to the finished assembly size. The sheet dimensions are important, but what matters during installation is whether the completed fill sections fit the available packing space. Both glued and hanging arrangements are available, depending on how the tower is built.

Product Specifications

  • Width: 750mm, 950mm
  • Length: Customizable
  • Thickness: Customizable
  • Corrugation Pitch: 20mm
  • Corrugation Angle: 90°
  • Material: PVC, CPVC, PP
  • Connection Method: Glue or hang

Cellular Fill with Flexible Assembly Dimensions

The 20mm corrugated sheets form a regular cellular passage structure when assembled. This arrangement provides defined spaces for water and air to move through the fill pack. The finished configuration can be adjusted according to the required packing dimensions and installation layout.

The 750mm and 950mm widths give customers two options when planning the fill arrangement. For projects where the original packing dimensions are not standard, we can adjust the length and sheet thickness rather than requiring the customer to change the existing tower structure.

Manufacturing and Assembly Options

We can supply this fill in glued assemblies or hanging configurations. For glued blocks, the required block dimensions should be confirmed before production. For hanging installations, the support arrangement and fixing requirements need to be checked to ensure the sheets can be installed correctly.

Material selection is also part of the production process. PVC, CPVC, and PP are available, and the appropriate choice depends on the cooling water temperature, chemical conditions, and other operating requirements.

Made to Match the Project

When preparing an order, we prefer to work from the actual packing dimensions rather than relying only on a general product description. Details such as the required width, length, sheet thickness, material, and installation method help us confirm the correct production arrangement.

With 750mm and 950mm width options, customizable dimensions, and different assembly methods, this cellular cooling tower fill can be supplied for new cooling tower projects or replacement requirements. Our focus is on producing fill sections that match the specified dimensions and are practical to install on site.

User Reviews
Oliver Williams
Oliver Williams
Water Treatment Equipment Manager

We have used their cooling tower packing products for several replacement applications. The cooling tower fill quality remains stable, and the customized sizes are suitable for different tower models. Their team understands industrial requirements and provides reliable service from inquiry to delivery.

Faisal Al Harbi
Faisal Al Harbi
Industrial Cooling System Consultant

The cooling tower fill supplied by this manufacturer was used for our commercial cooling system upgrade. The corrugated fill structure was well produced and matched our application requirements. We appreciate their professional communication, flexible customization options, and support during the purchasing process.

Hiroshi Tanaka
Hiroshi Tanaka
Mechanical Maintenance Supervisor

We selected their PP fill media for our cooling tower maintenance project. The product quality, packaging, and delivery arrangement met our expectations. Their technical team responded quickly and provided useful suggestions for installation and replacement. We are satisfied with this cooperation and look forward to future projects.

Daniel Richardson
Daniel Richardson
Cooling Tower Project Engineer

We purchased cooling tower fill materials for an industrial cooling system replacement project. The PVC film fill showed good quality consistency and accurate dimensions. The supplier provided detailed product information and helped us choose the suitable fill type according to our cooling tower design. The whole cooperation process was efficient and professional.

Hot Products
1220mm Standard-length Counter-flow Fill
1. 1220mm Standard-length Counter-flow Fill Introduction
1300/1320mm Dual-width Cross-flow Fill
1. 1300/1320mm Dual-width Cross-flow Fill Introduction De
Cooling Tower Drift Eliminator(1)
Height range: 145mmLength: CustomizedThickness: CustomizedPi
305-915 Multi-spec Counter-flow Fill
1. 305-915 Multi-spec Counter-flow Fill Introduction Adap
FAQ
Do you offer technical support for cooling tower fill installation?
We can provide installation guidance for cooling tower fill media projects worldwide. On-site assistance from our technical team can also be arranged when required.
How Long Does Cooling Tower Fill Production Take?
Standard production usually requires around 5–7 weeks after order approval, depending on cooling tower fill specifications and customization needs. Flexible arrangements can be discussed when required.
Is the cooling tower fill media resistant to high temperatures?
Yes, standard PVC cooling tower fill media is designed for continuous operation under normal thermal conditions. Customized material options can be discussed based on specific cooling system requirements.
What cooling systems are suitable for your cooling tower fill media?
Our cooling tower fill media is developed for various industrial cooling applications with stable heat exchange characteristics. Customized solutions can be provided based on different tower designs and operating conditions.
Send Us a Message
Code
Need help? Chat with us!